Thesis icon

Thesis

Moving-mask volume growing: a novel volume segmentation algorithm for medical images

Abstract:

Various physiological modelling studies require isolating the anatomy of interest from medical imaging. There exist a variety of segmentation algorithms, each particularly tailored for a specific anatomical region, imaging modality or physiological modelling study. Simulations of blood flow in brain vasculature require that the arterial and venous vasculature be isolated from angiographic modalities such as rotational planar angiography, computer tomography angiography and magnetic resonance angiography studies. Due to the tortuousity and apposition of the cerebral vessels to the highly vascular meninges and cranium, segmentation of these vessels is generally difficult. This work focuses on a novel algorithm for anatomy segmentation for specific use in the isolation of a particular region of the cerebrovascular anatomy associated with vessel pathology such as aneurysms and arteriovenous malformations. The algorithm uses geometric volume growing by means of comparing the intensities of neighbouring voxels originating from a user-determined seed point rather than fully automated segmentation by means of statistical algorithms that erroneously assume a normal distribution of intensity values in the image data. The research carried out shows that this novel algorithm can easily be incorporated into a simple processing chain for transoperative use by clinicians as the total time from a DICOM stack being imported to a STL geometry being created was on average under 5 minutes. Measurements carried out by clinicians of the anatomy in imaging data strongly correlate with the same measurements on the segmented volumes indicating high accuracy and precision in segmentation. In conclusion, although this algorithm is not suitable for all anatomies, modalities or applications, it shows promise for cerebrovascular studies in particular those where computer fluid dynamics or finite element method simulations of treatment are carried out. Further work should focus on improvements and tailoring the algorithm for other specific data and applications.

Actions

Access Document

Files:

Authors

More by this author
Division:
MPLS
Department:
Engineering Science
Department:
University of Oxford
Role:
Author

Contributors

Department:
University of Oxford
Role:
Supervisor



DOI:
Type of award:
MSc by Research
Level of award:
Masters
Awarding institution:
University of Oxford


UUID:
uuid:cb642e9b-530b-4144-ab55-3077ddde3309
Deposit date:
2017-11-10
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record