Environmental & orientation effects on the ultrasonic fatigue of a single-crystal nickel superalloy

Abstract:

Single-crystal superalloys are used in the high-pressure turbine blades of jet engines. Their fatigue performance is important for safety and cost. A better understanding of their fatigue lives to higher cycle numbers will aid this. Two key under-explored areas in the research are #1 lower temperature (≈ 450°C) as the focus has been placed on higher temperatures; #2 results from substantial and consistently controlled single-crystal orientations other than ubiquitous ⟨100⟩.

A novel ultrasonic fatigue method using meso-scale cantilevers was used to assess the fatigue performance of CMSX-4 from 104 to 109 cycles to failure, generating S-N curves.

The small-scale nature of the samples with this ultrasonic fatigue method allowed for the novel investigation of the fatigue crack initiation behaviour under different conditions. This is important as initiation dominates the high cycle fatigue life.

All results showed values greater than expected from the literature, which was proposed to be from a combination of bending fatigue and small-scale testing.

The 450°C results showed an improved fatigue performance compared to room temperature due to the anomalous yield strength phenomenon. The failure changed from shearing mode at room temperature to both shearing and opening at 450°C. ECCI micrographs showed the dislocation behaviour changing from planar slip to homogeneous slip.

The in-vacuum room temperature fatigue performance improved compared to the air-in tests. Unexpectedly, the fractographs suggest that opening mode fracture occurred under vacuum, likely linked to the enhanced performance, and proposed to be from significant localised heating around the crack tip under vacuum.

The crystal orientations of the samples from EBSD were consistent and close to the intended orientations. Cantilevers orientated near ⟨110⟩ showed similar in-air room temperature S-N curves compared to those orientated near ⟨100⟩. Both showed shearing mode fracture but had different fracture paths correlating with crystal plasticity finite element models and the literature. The slip behaviour of the two orientations was captured in ECCI and was compared with each other, the fracture behaviour, and the literature.

A novel method was developed and used to obtain/determine ECCI diffraction conditions with greater accuracy; this can impact other materials and applications.

Actions

Access Document

Files:

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Materials
Research group:
Oxford Micromechanics & Microstructure Group
Oxford college:
Mansfield College
Role:
Author
ORCID:
0000-0002-9220-2325

Contributors

Institution:
University of Oxford
Division:
MPLS
Department:
Materials
Research group:
Oxford Micromechanics & Microstructure Group
Role:
Supervisor
ORCID:
0000-0002-8801-4102
Institution:
King's College London
Role:
Supervisor


Rolls-Royce (United Kingdom) More from this funder
Funding agency for:
Scales, RJ
Grant:
DJT00530 – DJ00.01
Programme:
3.5-year full-time EPSRC DTP-CASE studentship with Rolls Royce,
Engineering and Physical Sciences Research Council More from this funder
Funding agency for:
Scales, RJ
Grant:
D4T00230 – DJ20.01
Programme:
3.5-year full-time EPSRC DTP-CASE studentship with Rolls Royce


DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
University of Oxford


Language:
English
Keywords:
Subjects:
Pubs id:
2407729
Local pid:
pubs:2407729
Deposit date:
2025-06-18
ARK identifier:

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP