Thesis icon

Thesis

Vasculature reconstruction from 3D cryomicrotome images

Abstract:

Background: Research in heart disease can be aided by modelling myocardial hemodynamics with knowledge of coronary pressure and vascular resistance measured from the geometry and morphometry of coronary vasculature. This study presents methods to automatically reconstruct accurate detailed coronary vascular anatomical models from high-resolution three-dimensional optical fluorescence cryomicrotomography image volumes for simulating blood flow in coronary arterial trees.

Methods: Images of fluorescent cast and bead particles perfused into the same heart comprise the vasculature and microsphere datasets, employed in a novel combined approach to measure vasculature and simulate a flow model on the extracted coronary vascular tree for estimating regional myocardial perfusion. The microspheres are used in two capacities - as fiducial biomarker point sources for measuring the image formation in order to accurately measure the vasculature dataset and as flowing particles for measuring regional myocardial perfusion through the reconstructed vasculature. A new model-based template-matching method of vascular radius estimation is proposed that incorporates a model of the optical fluorescent image formation measured from the microspheres and a template of the vessels’ tubular geometry.

Results: The new method reduced the error in vessel radius estimation from 42.9% to 0.6% in a 170 micrometer vessel as compared to the Full-Width Half Maximum method. Whole-organ porcine coronary vascular trees, automatically reconstructed with the proposed method, contained on the order of 92,000+ vessel segments in the range 0.03 – 1.9 mm radius. Discrepancy between the microsphere perfusion measurements and regional flow estimated with a 1-D steady state linear static blood flow simulation on the reconstructed vasculature was modelled with daughter-to-parent area ratio and branching angle as the parameters. Correcting the flow simulation by incorporating this model of disproportionate distribution of microspheres reduced the error from 24% to 7.4% in the estimation of fractional microsphere distribution in oblique branches with angles of 100°-120°.

Actions

Access Document

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Computer Science
Research group:
Computational Biology Group
Oxford college:
Balliol College
Role:
Author

Contributors

Role:
Supervisor
Role:
Supervisor


European Commission More from this funder
Funding agency for:
Goyal, A
Grant:
FP7-ICT-2007-224495:euHeart
Wellcome Trust More from this funder
Funding agency for:
Goyal, A
Grant:
FP7-ICT-2007-224495:euHeart
Engineering and Physical Sciences Research Council More from this funder
Funding agency for:
Goyal, A
Grant:
FP7-ICT-2007-224495:euHeart
Clarendon More from this funder
Funding agency for:
Goyal, A
Grant:
FP7-ICT-2007-224495:euHeart


Publication date:
2013
DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
Oxford University, UK

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP