Thesis icon

Thesis

Nanometrology for synchrotron X-ray mirrors

Abstract:

Key challenges for developing nanometrology are achieving high precision and accuracy under stringent environmental control to mitigate the impact of temperature, humidity, turbulence, and vibration. Additional complexities arise in accommodating the peculiarities of material behaviour at the nanoscale, in creating complex software to interpret large volumes of data efficiently, and in integrating various technologies within a single user-friendly instrument while managing costs and ensuring accessibility.

This thesis presents advancements in X-ray optics nanometrology using speckle-based analysis on the basis of comprehensive exploration of the full range of innovative techniques for ex situ characterisation of X-ray optics.

At the core of this research lies the intellectual challenge of obtaining successful characterisation of strongly curved X-ray mirror profiles (having radii of curvature smaller than 10m) in the form of 2D slope mapping data. The second challenge addressed in the thesis concerns providing the scientific community with an in-depth exploration and analysis of novel techniques and related metrology instrumentation. The thesis elaborates on the advancement of the mathematical models that underpin the new speckle-based metrology techniques. It also details the development of the requisite hardware and software tools.

The research commences with an in-depth background study of synchrotron X-ray mirrors and the necessity for enhanced metrology to underpin further progress at large scale science facilities, such as synchrotron light sources. A thorough literature review is presented to evaluate the existing non-contact metrology methods, including Pencil Beam Interferometer, Long Trace Profiler, Nanometre Optical Metrology, Fizeau Interferometer, and Stitching Micro-Interferometer.

The detailed study of the Speckle Angle Measurement (SAM) technique is presented. The methodology of SAM is expanded upon, including the experimental setup, data acquisition, precision, accuracy, calibration processes, and simulation. Critical analysis is presented of the principal factors influencing SAM, namely, the scanning head rotation and tilting angle of the Sample Under Test (SUT). The findings provide a solid demonstration of the effectiveness of SAM in the complete range of required capabilities, including the calibration, stability, simulation, and characterisation of various optics, including elliptical X-ray mirrors. The comparison between simulated and experimental results provides validation of the accuracy and applicability of SAM. The thesis concludes by highlighting the potential of SAM for applications such as Ion Beam Figuring at Diamond Light Source (DLS) and by highlighting further areas of research.

Actions

Access Document

Files:

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Engineering Science
Role:
Author

Contributors

Institution:
University of Oxford
Division:
MPLS
Department:
Engineering Science
Role:
Supervisor
Role:
Supervisor
Role:
Supervisor


Engineering and Physical Sciences Research Council More from this funder
Funding agency for:
Moriconi, S
Grant:
EP/R513295/1
Programme:
Doctoral Training Programme (DTP)


DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
University of Oxford

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP