Thesis
Automated quality control by application of machine learning techniques for quantitative liver MRI
- Abstract:
- Quantitative magnetic resonance imaging (qMRI) and multi-parametric MRI are being increasingly used to diagnose and monitor liver diseases such as non-alcoholic fatty liver disease (NAFLD). These acquisitions are comparably more complicated than traditional T1-weighted and T2-weighted MRI scans and are also more prone to image quality is- sues and artefacts. In order for the output of the qMRI scans to be useable, they must undergo a rigorous and often lengthy quality control (QC). This manual QC is prone to human error and subjective. Additionally, with the development of new qMRI tech- niques, this leads to the manifestation of new quality issues. This thesis focuses on the development and implementation of automated QC processes for liver qMRI scans, that is where possible tag-free such that the process can be adapted to different imag- ing techniques. These automated QC processes were implemented using a variety of machine learning (ML) and deep learning (DL) approaches. These methods, developed on T1 mapping in UKBiobank, were designed to output metrics from the MRI scans that could be used to identify a specific quality issue, such as in chapter 3, or give a more general indication of the image quality in chapter 4. Furthermore, it was hypothe- sised that the introduction of associated meta-data, such as patient factors and scanning parameters, into these deep learning models would increase overall performance. This was explored in chapter 5. Finally, in order to assess the utility of our developed al- gorithms in a wider setting except for T1 mapping in UKBiobank, we tested it in two settings. Pilot study one assessed the utility of the model in T1 mapping in a separate study (CoverScan). Pilot study two assessed the utility of the model in a different qMRI acquisition; proton density fat fraction (PDFF) acquisitions from UKBiobank.
Actions
Access Document
- Files:
-
-
(Preview, Dissemination version, pdf, 18.8MB, Terms of use)
-
Authors
Contributors
+ Grau Colomer, V
- Institution:
- University of Oxford
- Division:
- MPLS
- Department:
- Engineering Science
- Role:
- Supervisor
- ORCID:
- 0000-0001-8139-3480
+ Robson, M
- Role:
- Supervisor
+ Biasiolli, L
- Institution:
- University of Oxford
- Division:
- MSD
- Department:
- RDM
- Sub department:
- RDM Cardiovascular Medicine
- Role:
- Supervisor
- ORCID:
- 0000-0002-0452-8756
+
Medical Research Council
More from this funder
- Grant:
- EP/L016052/1
- Programme:
- Oxford Nottingham Biomedical Imaging DTC
+
Engineering and Physical Sciences Research Council
More from this funder
- Grant:
- EP/L016052/1
- Programme:
- Oxford Nottingham Biomedical Imaging DTC
- DOI:
- Type of award:
- DPhil
- Level of award:
- Doctoral
- Awarding institution:
- University of Oxford
- Language:
-
English
- Keywords:
- Subjects:
- Deposit date:
-
2024-02-13
- ARK identifier:
Terms of use
- Copyright holder:
- Hill, C
- Copyright date:
- 2021
If you are the owner of this record, you can report an update to it here: Report update to this record