Micromechanical studies of ultrasonic fatigue in Ti-6Al-4V

Abstract:
This thesis investigates the micromechanics of fatigue in Ti-6Al-4V through the development and application of an ultrasonic bending fatigue rig, combined with advanced electron backscatter diffraction (EBSD) characterisation techniques and supporting computational approaches. The fatigue life was examined across a wide life regime to very high cycle fatigue (VHCF), with particular emphasis on early crack formation and microstructure-sensitive short crack growth

The sample preparation method was first evaluated in terms of the effects on fatigue performance. The removal of redeposit layers and improving surface quality by electropolishing were found to moderately improve fatigue strength of approximately 50 MPa at 107 cycles and up to 200 MPa at 109cycles. Comparisons with lower frequency fatigue data revealed a frequency dependence of fatigue strength. The results indicate that strain rate sensitivity in Ti-6Al-4V is most pronounced at low frequencies and diminishes as testing frequency increases. Environmental effects were also substantial: fatigue testing in high vacuum (10−6 mbar) produced higher fatigue strengths and markedly lower crack propagation rates than tests conducted in air.

Fractography and trace analysis demonstrated that fatigue crack initiation is inherently crystallographic, with all observed initiation events occurring on near-basal planes. While no direct correlation was found between global texture and fatigue strength, a strong relationship emerged when considering local microtexture at fatigue crack initiation (FCI) and ’hotspot’ regions. Clustering of favourably oriented grains promoted both reduced fatigue strength and accelerated short crack growth, whereas grain size alone showed no systematic influence. Local crack growth retardation and crack path deflections were linked to slip system transitions and grain boundary interactions, highlighting the microstructure-sensitive nature of short crack propagation.

Lastly, a different reference pattern selection technique for high-angular resolution EBSD (HR-EBSD) was proposed. A multi-reference pattern approach was introduced to mitigate reference-pattern bias in lattice rotation gradient and geometrically necessary dislocation (GND) density calculations, producing more physically consistent strain and GND maps. This framework was applied to interrupted fatigue experiments, enabling direct observation of elastic strain and dislocation evolution ahead of a fatigue crack tip over a quarter fatigue cycle.

Actions

Access Document

Files:

Authors

More by this author
Institution:
University of Oxford
Division:
MPLS
Department:
Materials
Sub department:
Materials
Research group:
Oxford Micromechanics & Microstructure Group
Oxford college:
Corpus Christi College
Role:
Author
ORCID:
0000-0002-7958-4621

Contributors

Institution:
University of Oxford
Division:
MPLS
Department:
Materials
Research group:
Oxford Micromechanics & Microstructure Group
Role:
Supervisor
ORCID:
0000-0002-8801-4102
Institution:
King's College London
Role:
Supervisor


DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
University of Oxford

Terms of use


Views and Downloads

Views and downloads will return soon






If you are the owner of this record, you can report an update to it here: Report update to this record

TO TOP