Feasibility and constraints of Bragg peak FLASH proton therapy beam delivery and treatment planning

Abstract:
Spread-out Bragg peak FLASH proton therapy (FLASH-PT) aims to use ultra-high dose rates to elicit a normal tissue sparing effect whilst maintaining the anti-tumour effectiveness of conventional proton therapy. Conventional energy-modulation techniques used in intensity modulated proton therapy (IMPT) are not fast enough to achieve ultra-high dose rates (≥40 Gy/s); instead, FLASH-PT utilises monoenergetic protons (230 MeV) combined with static energy degraders. This thesis investigates the feasibility and constraints of FLASH-modified beam delivery and treatment planning in achieving dose distributions comparable to IMPT, forming an essential part of the clinical implementation of FLASH-PT. Chapter 3 investigates the feasibility of FLASH-PT treatment planning compared to IMPT using a research treatment planning system incorporating dose rate optimisation. Margin-based FLASH-PT plans achieve sufficient ultra-high dose rate coverage. However, they demonstrate inferior target coverage and increased doses to organs at risk (OARs) compared to IMPT. Chapter 4 assesses the impact of dose rate optimisation on the quality of FLASH-PT treatment plans by utilising two treatment planning systems, one with and one without dose rate optimisation. Non-dose rate optimised planning and robust optimisation improves plan quality without compromising dose rates or increasing OAR doses; however, target coverage remains inferior to IMPT in worst-case scenarios. Finally, Chapter 5 explores whether reducing the initial beam energy from 228 MeV to that used in IMPT plans, thereby decreasing the required range shifter thickness, can improve plan quality by reducing scattering and range straggling. Non-maximal energy FLASH-PT plans can achieve IMPT-equivalent target coverage, whilst reducing the gap between FLASH-PT and IMPT doses to OARs, at the expense of lower dose rates. This work advances the understanding of relevant treatment planning optimisation techniques and beam delivery modifications, collectively improving the feasibility of spread-out Bragg peak FLASH proton therapy.

Actions

Access Document

Files:

Authors

More by this author
Institution:
University of Oxford
Division:
MSD
Department:
Oncology
Role:
Author
ORCID:
0009-0003-6668-1195

Contributors

Institution:
University of Oxford
Division:
MSD
Department:
Oncology
Role:
Supervisor
ORCID:
0000-0003-0300-5790
Institution:
University of Oxford
Division:
MSD
Department:
Oncology
Role:
Examiner
Institution:
Quirónsalud Proton Therapy Centre, Spain
Role:
Examiner


Medical Research Council More from this funder
Grant:
MR/W006731/1
Grant:
MR/N013468/1
Oxford Institute of Radiation Oncology More from this funder
Grant:
MC_ST_OIRO_2019


DOI:
Type of award:
DPhil
Level of award:
Doctoral
Awarding institution:
University of Oxford