Sensitivity and accuracy limits of molecular imaging in fluorescence guided surgery
- Abstract:
-
Fluorescence guided surgery (FGS) is an emerging imaging modality seeking to improve optical contrast in the near infrared (NIR). FGS offers real time imaging capabilities to help surgeons identify tissues of interest with higher precision and specificity during surgery. The increased contrast is provided by fluorescence emission from non-specific or specific fluorescent markers.
Many commercial imagers have been developed for FGS, with several achieving FDA approval for clinical use. However, little information is available regarding absolute sensitivity of the detection systems or amount of excitation light produced in physical units. In light of this, attempts have been made to formulate a calibration standard. Previously published calibration methods have involved the use of composite phantoms, which require chemical preparation, may suffer from inner filter effects* and have a limited shelf life. This work outlines a new electronic calibration device for FGS, consisting of a light emitting module and a light detection module. Their purpose is to measure the detection sensitivity to NIR photons for various NIR wavelengths (in SI units of photons/s/cm2) and to measure the excitation light available as a function of working distance (in SI units of mW/cm2).
The second part of this work is concerned with the development of a novel ex-vivo FGS imager. This ex-vivo imager seeks to potentially improve outcomes of FGS surgical procedures by evaluating surgical margins following tissue resection. This will help the surgeon to quickly determine whether further surgery is needed. The ex-vivo imager uses a custom designed excitation light source to maximise fluorophore excitation at numerous wavelengths and employs a low readout noise chilled NIR-sensitive camera. Furthermore, spectral unmixing approaches may be explored to remove confounding autofluorescence signals. These features of the imager are designed to maximise imaging contrast and tumour-to-background ratio.
* Inner filter effects involve the process of absorption of fluorescence emission within the composite phantom following excitation by the FGS imager being calibrated.
Actions
Access Document
- Files:
-
-
(Preview, Dissemination version, pdf, 4.4MB, Terms of use)
-
Authors
- Grant:
- C1380/A20600
- Programme:
- Science Committee – Studentships
- DOI:
- Type of award:
- MSc by Research
- Level of award:
- Masters
- Awarding institution:
- University of Oxford
- Language:
-
English
- Deposit date:
-
2021-04-13
- ARK identifier:
Terms of use
- Copyright holder:
- Fry, S
- Copyright date:
- 2020
If you are the owner of this record, you can report an update to it here: Report update to this record